Agent数码Reaper
测试完成提示信息说明:谢谢参考!
⑴ TEST Complete: OK 表示测试完成,各项参数满足要求
⑵ TEST Fail: VOL LOW 表示测试出错,电压偏低
⑶ TEST Fail: VOL HIGH 表示测试出错,电压偏高
⑷ TEST Fail: IMP LOW 表示测试出错,内阻偏低
⑸ TEST Fail: IMP HIGH 表示测试出错,内阻偏高
⑹ TEST Fail: CHARGE ERR 表示测试出错,充电功能故障
⑺ TEST Fail: DISCHR ERR 表示测试出错,放电功能故障
⑻ TEST Fail: OVC LOW 表示测试出错,过流保护电流偏低
⑼ TEST Fail: OVC HIGH 表示测试出错,过流保护电流偏高
⑽ TEST Fail: R1 LOW 表示测试出错,识别电阻1阻值偏低
⑾ TEST Fail: R1 HIGH 表示测试出错,识别电阻I阻值偏高
⑿ TEST Fail: R2 LOW 表示测试出错,识别电阻2阻值偏低
⒀ TEST Fail: R2 HIGH 表示测试出错,识别电阻2阻值偏高
⒁ TEST Fail: ID ERROR 表示测试出错,通讯码片测试不通过。
⒂ TEST Fail: SHORT ERR 表示测试出错,短路保护功能不正常
花小卷2010
1.Purpose: Test the NL210 semi-processed goods battery of each item function, examination possibility emergence of break down, for the convenience of cancellation and improvement. 2. Test machine function: 2.1 Supply voltage:The DC 21 V ± 0.2 V, the electric current 2 A be above. 2.2 Main function:Refresh of the test semi-processed goods battery, lead Chong, turn on electricity, lead put and battery short-circuit proof etc. each item electricity function. 3, the tool use: 3.1 The NL210 semi-processed goods/finished product test. 3.2 Direct current power supply. 3.3 The NL210 semi-processed goods battery. 4. Test process and item: Mount power supply, MODE switch choice arrive HALF file, put the NL210 semi-processed goods battery into test test inside slot, probe push forward battery port, press good press cover(such as attach diagram 1), POWER switch choice arrive ON file, test auto beginning. 4.1 Edition and date manifestation: LCD manifestation: NL210 M_FN TEST V2.0 2006-06 4.2 Battery+A port test: LCD manifestation: Port-A Test, test battery port+A, if the port Mayday press to output, LCD manifestation: The Port-A Test Fail. 4.3 R_IND electric resistance test: LCD manifestation:R_IND Test, the test battery IND carry a string of connect of to ground 47 K electric resistance, such as the resistivity is in the ± 5% error margin scope, is OK, otherwise LCD manifestation:R_IND Test Fail. 4.4 Refresh a test: LCD manifestation:Charge Test, the test battery refresh function, if the battery can't be normal to refresh, LCD manifestation:Charge Fail. 4.5 Refresh not a protection upper limit a test: LCD manifestation:The Upper Test of the No-Protect, the test semi-processed goods battery refresh not protection upper limit function, if the battery be following to stop refresh in the 16.7 V, LCD manifestation:The Upper Fail of the No-Protect. 4.6 Lead to refresh a test: LCD manifestation:Overcharge Test, the test semi-processed goods battery lead to refresh function, if the battery electric voltage attain a 18.0 V can't stop refresh, LCD manifestation:Overcharge Fail. 4.7 Turn on electricity a test: LCD manifestation:Discharge Test, the test finished product battery turn on electricity function, if the battery can't turn on electricity, LCD manifestation:Discharge Fail. 4.8 Turn on electricity not a protection to descend a limit test: LCD manifestation: The Lower Test of the No-Protect, test the semi-processed goods battery don't under the protection turn on electricity limit function, if the battery be above to stop turn on electricity in the 12.0 V, LCD manifestation:the Lower Fail of the No-Protect. 4.9 Lead to turn on electricity a test: LCD manifestation:Overdischarge Test, the test semi-processed goods battery lead to turn on electricity protection function, if the battery electric voltage be low to the 9.2 V can't stop turn on electricity, LCD manifestation:Overdischarge Fail. 4.10 Short-circuit proof test: LCD manifestation:Short_Circuit Test, the test short-circuit proof function of the semi-processed goods battery, if battery short-circuit proof's delaying time to outrun empress scope or short circuit battery can't refresh, LCD manifestation:Short_Circuit Test Fail. 4.11 LED test: At each test item test, observation the battery LED1 indicator should Heng bright, LED2-5 should in order and one by one in order point bright, then in order and one by one in order put out, if the LED2-5 be not bright or in the meantime point bright phenomenon, all is bad. 4.11 The test complete: After each item function of the semi-processed goods battery test is qualified, LCD manifestation:The NL210 M_FN TEST Pass.Such as need again test, then replace battery, press RESET key, auto carry on test. 5, external appearance check: Had no outer shell to row harm, the super voice was bad etc.. 6, regulation: 6.1 In the test if meet any bad phenomenon, can press RESET key afresh test. 6.2 Can't long time press RESET key, MCU beginning start to turn of big electric current possibility damage test machine parts. 6.3 Test process in, this test be only rightness above-mentioned test item valid. 7, attach diagram:分数太低了噻!累死个人噻!
优质英语培训问答知识库